Koeffizient des Faser-Bragg-Gitter (FBG) Temperatursensors - Kalibrierungsfunktion für 100°C FBG Thermometer

OFSCN® 100-degree Celsius capillary seamless steel tube fiber bragg grating (FBG) temperature sensors (FBG thermometers) produced by DCYS undergo calibration during the manufacturing process. They are accompanied by the basic temperature coefficient (also known as calibration coefficient or calibration function) of the fiber bragg grating sensor. The following is a brief description of the calibration of this product:

Inhaltsverzeichnis:

1. Produktstruktur des 100°C Faser-Bragg-Gitter Temperatursensors

2. Werksprüfbericht für 100°C Faser-Bragg-Gitter Temperatursensor - Kalibrierungstemperaturkoeffizienten

1. Product Structure of OFSCN® 100°C Capillary Seamless Steel Tube Fiber Bragg Grating Temperature Sensor:

OFSCN® 100°C Capillary Seamless Steel Tube Fiber Bragg Grating Temperature Sensors (FBG Thermometers) are protected by a full-metal encapsulation to safeguard the fiber bragg grating (FBG). The standard product has a diameter of 0.9 millimeters, and the overall structure and the product itself are shown in Abbildung 1, 2, and 3:

Physikalisches Diagramm des OFSCN® Kapillarnahtlosen Stahlrohr-FBG-Temperatur-/Dehnungs-/Spannungssensors (Teil davon)

Abbildung 1

Physikalisches Diagramm des OFSCN® FBG-Temperatursensors mit nahtlosem Kapillarstahlrohr Hauptstruktur des OFSCN® Kapillarnahtlosen Stahlrohrs FBG Senso

Abbildung 2

Abbildung 3


Die Stecker und Endstücke sind in den Abbildungen 4 und 5 dargestellt:

Faserverbinder des OFSCN® Kapillarnahtlosen Stahlrohr-FBG-Sensors Endstück des OFSCN® Kapillarnahtlosen Stahlrohr-FBG-Sensors

Abbildung 4

Abbildung 5

Due to the unique stainless steel seamless tube patent packaging technology und our special processing techniques applied to the OFSCN® 100-degree Celsius capillary seamless steel tube fiber bragg grating temperature sensor (FBG thermometer), it possesses the following features: high sensitivity, fast thermal conduction, good accuracy, small size, light weight, high tensile und compressive strength, high temperature resistance, waterproof und moisture-proof properties, non-flammable, und corrosion resistance.

2. Factory Test Report for OFSCN® 100°C Capillay Seamless Steel Tube Fiber Bragg Grating Temperature Sensor - Calibration Coefficient Graph:

High accuracy is the lifeline of DCYS's products, und this characteristic is verified through the test reports of each sensor we produce, as shown in the following figure:

Kalibrierungsdiagramm der Wellenlänge und Temperatur des OFSCN® 100°C-Kapillar-FBG-Temperatursensors mit nahtlosem Stahlrohr

Abbildung 6

Abbildung 6 above shows the measured chart of the calibration coefficient (calibration function) of an actual sold OFSCN® 100-degree Celsius capillary seamless steel tube fiber bragg grating temperature sensor. The curve illustrates the correlation between the wavelength variation of the sensor and temperature change, with a test range from room temperature to 100 degrees Celsius. Since this sensor can be used up to a maximum of 120 degrees Celsius, if requested by the customer, we can also provide calibration for temperatures ranging from room temperature to 120 degrees Celsius, with a calibration temperature interval of approximately 10 degrees Celsius.

Im Gegensatz zur Legende wird der offizielle Werksbericht auch spezifische Wellenlängen- und Temperaturwerte liefern. Für allgemeine Temperaturmessanforderungen kann dieser Kalibrierungskoeffizient direkt verwendet werden.

Each OFSCN® 100-degree Celsius capillary seamless steel tube fiber bragg grating temperature sensor (FBG thermometer) has a unique calibration coefficient (calibration function), which is tested und recorded by the Quality Inspection Department of DCYS, und can be accessed by customers at any time on the company's official website. In our experience, the R-squared value of the polynomial equation for the calibration function can reach 0.9995 or higher.

Our philosophy is: 'OFSCN®, Make Optical Fiber Stronger!'

  • DCYS is a professional 100°C FBG-Temperatursensor manufacturer, providing 100°C FBG-Temperatursensor calibration method, calibration experiment, test report, temperature coefficient, calibration function and other information; 100°C fiber bragg grating temperature sensor brand is 'OFSCN'.