Femtosaniye Fiber Bragg Izgarası (FBG) sıcaklık sensörünün katsayısı - 500°C FBG termometre için Fabrika Kalibrasyon Fonksiyonu, -4.6℃ ila 450℃ Aralığı
OFSCN® 500°C Capillary Seamless Steel Tube Fiber Bragg Grating Temperature Sensors (FBG Thermometers) produced by DCYS undergo calibration before leaving the factory, ve the basic temperature coefficients (also known as calibration coefficients or calibration functions) for the fiber bragg grating sensors are provided along with the product. Here is a brief explanation of the calibration for this product:
İçindekiler:
| 1. Femtosaniye Fiber Bragg Grating Sıcaklık Sensörünün Ürün Yapısı |
1.Product Structure of OFSCN® 500°C Capillary® Seamless Steel Tube Femtosecond Fiber Bragg Grating Temperature Sensor:
OFSCN® 500°C Capillary Seamless Steel Tube Fiber Bragg Grating Temperature Sensors (FBG Thermometers) are protected by a full-metal encapsulation to safeguard the fiber bragg grating (FBG). The standard product has a diameter of 2.0 millimeters and features a three-layer metal pipe nested structure. It encapsulates a high-temperature-resistant femtosecond fiber bragg grating (Femtosecond FBG). The overall structure and the product itself are shown in Şekil 1, 2, and 3:
![]() |
|
|
Şekil 1 |
|
![]() |
![]() |
| Şekil 2 |
Şekil 3 |
Konektörler ve uçlar Şekil 4 ve 5'te gösterilmiştir:
![]() |
![]() |
|
Şekil 4 |
Şekil 5 |
2. Factory Test Report for OFSCN® 500°C Capillary Seamless Steel Tube Femtosecond Fiber Bragg Grating Temperature Sensor - Calibration Coefficient Graph:
High accuracy is the lifeline of DCYS's products, ve this characteristic is verified through the test reports of each sensor we produce, as shown in the following figure:
![]() |
| Şekil 6 |
Şekil 6 shows the measured graph of the calibration coefficient (calibration function) of an actual sold OFSCN® 500°C Capillary Seamless Steel Tube Fiber Bragg Grating Temperature Sensor (FBG Thermometer). This curve displays the corresponding relationship between the sensor's wavelength variation and temperature change. As this sensor can be used at higher temperatures, we provide calibration for temperatures ranging from room temperature to 450°C, with calibration temperature intervals of approximately 30°C (not strictly enforced).
Lejantın aksine, resmi fabrika raporunda belirli dalgaboyu değerleri ve sıcaklık değerleri de sunmaktayız. Genel sıcaklık ölçümleri için bu kalibrasyon katsayısı doğrudan kullanılabilir.
Each OFSCN® 500°C Capillary Seamless Steel Tube Fiber Bragg Grating Temperature Sensor has a unique calibration coefficient (calibration function), which is tested ve determined by the Quality Inspection Department of DCYS. It is recorded on the company's official website for customers to query at any time. Based on our experience, the R-square value of the binomial function is generally above 0.9995.
Our philosophy is: 'OFSCN®, make optical fiber stronger!'
DCYS is a professional 500°C FBG temperature sensor manufacturer, providing 500°C FBG temperature sensor calibration method, calibration experiment, test report, temperature coefficient, calibration function and Diğer information; 500°C fiber bragg grating temperature sensor brand is 'OFSCN'.