Temperature Coefficient of Femtosecond Fiber Bragg Grating (FBG) Sensor- Factory Calibration Function for 800°C FBG Thermometer, Ranging from -16 to 806°C and 524 to 1000°C

  • DCYS is a professional 800°C FBG temperature sensor manufacturer, providing 800°C FBG temperature sensor calibration method, calibration experiment, test report, temperature coefficient, calibration function and other information; 800°C fiber bragg grating temperature sensor brand is "OFSCN".

The OFSCN® 800°C Capillary Seamless Steel Tube Fiber Bragg Grating temperature sensor (FBG thermometer) , manufactured by DCYS, undergoes temperature calibration before leaving the factory. Along with the product, basic temperature coefficients (also known as calibration coefficients or calibration functions) of the fiber optic grating sensor are provided. The following is a brief description of the temperature calibration of the product at the time of shipment:

Table of Contents:

I. Product Structure of the 800°C Capillary® Femtosecond Fiber Bragg Grating Temperature Sensor

II. Factory Calibration Report of the Femtosecond Fiber Bragg Grating Temperature Sensor - Temperature Coefficient at -1000°C

I. Product Structure of the OFSCN® 800°C Capillary Femtosecond Fiber Bragg Grating Temperature Sensor

The OFSCN® 800°C Capillary Seamless Steel Tube Fiber Bragg Grating Temperature Sensor (FBG thermometer) adopts a fully metallic packaging method to protect the FBG. The standard product has a diameter of 2.0 millimeters and consists of a three-layer seamless steel tube nested structure. It encapsulates a high-temperature-resistant femtosecond fiber bragg grating (Femtosecond FBG). The overall structure and product are shown in Figure 1, 2, and 3 below:

 

Physical Diagram of OFSCN® Capillary Seamless Steel Tube FBG Temperature/ Strain/Stress Sensor (Part of it)

Figure 1

Physical Diagram of OFSCN® Capillary Seamless Steel Tube FBG Temperature Sensor Main Structure of OFSCN® Capillary Seamless Steel Tube FBG Sensor

Figure  2

Figure 3


The connectors and Tail ends are shown in Figures 4 and 5 below:

Fiber Connector of OFSCN® Capillary Seamless Steel Tube FBG Sensor Tail end of OFSCN® Capillary Seamless Steel Tube FBG Sensor

Figures 4

Figures 5

Due to the unique stainless steel seamless tube patented packaging technology used in the OFSCN® 800°C Capillary Seamless Steel Tube Fiber Bragg Grating Temperature Sensor (FBG thermometer), as well as our special process treatment, it possesses high sensitivity, fast thermal conduction, good accuracy, small size, light weight, high tensile strength, high pressure resistance, high temperature resistance, water and moisture resistance, non-combustibility, and corrosion resistance.

 

II. Factory Test Report of the OFSCN® 800°C Capillary® Seamless Steel Pipe Femtosecond Fiber Bragg Grating Temperature Senso - Temperature Coefficient Calibration Graph 

High accuracy is the lifeline of DCYS's products, a feature that is verified through the test reports of each sensor produced, as shown in the following figure:

Measured Diagram of Wavelength and Temperature for OFSCN® 800°C Capillary Seamless Steel Tube FBG Temperature Sensor

Figure 6

Figure 6 displays the actual measurement graph of the temperature coefficient (calibration coefficient, calibration function) of a sold OFSCN® 800°C Capillary Seamless Steel Tube Fiber Bragg Grating Temperature Sensor (FBG thermometer). This curve shows the correspondence between the sensor's wavelength variation and temperature change. The test range is from -16 to 806°C, with temperature calibration intervals of approximately 30°C (not strictly enforced).

Calibration Diagram of Wavelength and Temperature of OFSCN® 800°C Capillary Seamless Steel Tube FBG Temperature Sensor

Figure 7

The OFSCN® 800°C Capillary Seamless Steel Tube Fiber Bragg Grating Temperature Sensor (FBG thermometer) can be temporarily used at higher temperatures (duration of use not tested, repeatability to be determined). Figure 7 presents the actual measurement graph of the temperature coefficient (calibration coefficient, calibration function) of a specific OFSCN® 800°C Capillary Seamless Steel Tube FBG Temperature Sensor (FBG thermometer). This curve shows the correspondence between the sensor's wavelength variation and temperature change. The main test temperature range is from 524 to 1001°C (initial temperature of 53°C), with temperature calibration intervals of approximately 40°C (not strictly enforced).

Contrary to the legend, in the official factory report, specific wavelength and temperature values will be provided. For general temperature measurements, this calibration coefficient can be directly used.

Each OFSCN® 800°C Capillary Seamless Steel Tube Fiber Bragg Grating Temperature Sensor has a unique temperature coefficient (calibration coefficient, calibration function). This coefficient (function) is tested and determined by the Quality Inspection Department of DCYS and recorded on the company's official website for customers to check at any time. Based on our experience, the R-square value of the binomial function is generally above 0.9995.

Our philosophy is: "OFSCN®, make optical fiber stronger!"